Camspec Single and Double Beam UV Visible Spectrophotomers Products

#M105 CAMSPEC M105 - Visible spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508076609/wyuru5jqbi6rzjfd5zsu.jpg
CAMSPEC M105 - Easily used Visible spectrophotometer
Easily used Visible Spectrophotometer Model M105 is a robustly built instrument giving a very high level of performance.
Wavelength is conveniently set using a rotary control. The instrument is then ready for use within just a few minutes from switch on. A membrane keyboard positioned next to the large, clear LCD display, allows the operator to rapidly switch between %T and Absorbance and to set Zero Absorbance. The bandpass of 20nm is well matched to the wavelength range of 335 to 1000nm.
The remarkable stability and accuracy of the instruments will be welcomed by all types of laboratories. The sample compartment accepts either standard 10mm rectangular cells also known as cuvettes, or test-tubes. A special accessory is available for different diameter Test tubes. The USB output provides a convenient link to a PC or a printer for a hardcopy. A low-cost application program, which runs under Windows™ 10, 9x, Xp, 7, or 8, includes the facility to create calibration curves on screen.
See our Standards for UV-Vis spectrophotometers
Specifications
• Display -Digital L.C.D.
• Light source - Tungsten-Halogen
• Monochromator - 1200 lines/mm gratingDetectors - Silicon Photodiode
• Wavelength Range - 335 - 1000nm
• Wavelength Accuracy - ± 2 nm
• Wavelength Repeatability - ± 1 nm
• Noise - < 0.001A @ 500nm 0A
• Zero Drift - < 0.003A per hour after warm-up
• Bandpass - 20 nm
• Stray Light - <0.1%T @ 340 nm
• Photometric Accuracy - +/- 1% 0-1 A
• Photometric Range - 0 to 2, 0-125%T
• Printer Interface - USB for printer.
• Computer Interface - USB for PC control
• Power Requirements - 110/120V, 220/230V, 50/60 Hz, 60VA
• Dimensions - 408 x 308 x 185mm packed 645 x 535 x 370mm
• Weight - 6Kg packed 9Kg
This easily used visible spectrophotometer has been in use in university teaching laboratories, industrial laboratories, hospital laboratories and water treatment companies throughout the world.

https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508076609/wyuru5jqbi6rzjfd5zsu.jpg

#M106 CAMSPEC M106 Visible spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077098/zd4iv0h9nqw4gg63sbpe.jpg
This easily used QC visible spectrophotometer is a robustly built student and quality control visible spectrophotometer, combining a surprisingly high level of performance with a budget price. Wavelength is conveniently set using the rotary control and the instrument is ready for use within just a few minutes from switch-on. A membrane keyboard positioned next to the large, clear LCD display, allows the operator to rapidly switch between %T, Absorbance and Concentration modes and to set Zero Abs. The narrow 10 nm bandpass is ideally matched to the wavelength range of 335-1000nm.
This easily used QC visible spectrophotometer model also has remarkable stability and accuracy which will be welcomed by quality control managers and teaching laboratories. The sample compartment accepts either standard 10mm rectangular cuvettes, or test-tubes and the RS232 output provides a convenient link to a PC or digital printer for hardcopy. A low-cost, optional application program, which runs under Windows™ operating systems, includes the facility to create calibration curves on screen.

The remarkable stability and accuracy of the instrument will be welcomed by quality control and teaching laboratories. The sample compartment accepts either standard 10mm rectangular cuvettes, including disposable semi-micro cuvettes, or test-tubes of various sizes (with a special tube holder). The USB output provides a convenient link to a PC, and an RS232 socket for a digital printer is available. A low-cost application program, which runs under Windows™ 10, 9x, Xp, 7, or 8, includes the facility to create calibration curves on screen.
See our Standards for UV-Vis spectrophotometers
Specifications of this easily used QC visible spectrophotometer model M106
• Display - LCD Display
• Light source - Tungsten-Halogen
• Monochromator - 1200 lines/mm grating
• Detector - Silicon Photodiode
• Wavelength Range - 335 - 1000nm
• Wavelength Accuracy - ± 2 nm
• Wavelength Repeatability - ± 1 nm
• Noise - < 0.001A @ 500nm 0A
• Zero Drift - < 0.003A per hour after warm-up
• Bandpass - 10 nm
• Stray Light - <0.1%T @ 340 nm
• Photometric Accuracy - +/- 1% 0-1 A
• Photometric Range - 0 to 2A, 0-125%T and -9999C and +9999C
• Printer Interface - RS 232 for printer
• Computer Interface - USB for PC control
• Power Requirements - 110/120V, 220/230V, 50/60 Hz, 60VA
• Dimensions - 408 x 308 x 185mm packed 645 x 535 x 370mm
• Weight - 6Kg packed 9Kg
This easily used visible spectrophotometer has been in use in university teaching laboratories, industrial laboratories, hospital laboratories and water treatment companies throughout the world.
https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077098/zd4iv0h9nqw4gg63sbpe.jpg

#M107 CAMSPEC M107 Visible spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077177/kgzmam2zphoi48exja0k.jpg
This M107 manual wavelength controlled visible spectrophotometer, uses a simple mechanism to select the wavelength and order sorting filters. This feature offers permanent wavelength calibration and eliminates wavelength initialisation routines at switch on. Signal processing and results display are microprocessor controlled, the narrow 5nm bandpass gives improved analytical sensitivity. The outstanding optical performance of this visible spectrophotometer is also indicated by the low zero drift (less than 0.001 Abs/Hour) and the low stray light (0.1%T @ 340nm).
The RS232 output provides a convenient link to a PC or serial printer for hardcopy. A low-cost application program which runs under Windows™ includes the facility to create calibration curves. The reaction kinetics program, when used with the thermostatted cell holder accessory, provides an excellent low-cost enzyme analysis system.

Using a reconfigured grating monochromator from the successful M105 and M106 visible spectrophotometer models, the M107 offers more performance and versatility with only a modest price difference. The large sample compartment allows the use of a wide range of accessories, including a 4-position cell changer with holder for cell pathlengths up to 50mm. A membrane keyboard positioned next to the large, clear LCD display allows, the operator to rapidly switch between %T, Abs and Concentration modes and to set Zero Abs.
The signal processing and results display of this visible spectrophotometer are microprocessor controlled and the narrow 5nm bandpass gives improved analytical sensitivity. The outstanding optical performance is also indicated by the low zero drift (<0.001A/hr) and the low stray light (0.1%T @ 340nm). Wavelength selection is by rotary control. This simple mechanism automatically selects the order sorting filters, offers permanent wavelength calibration and eliminates wavelength initialisation routines at switch-on.
The USB output provides a convenient link to a PC, the RS232 socket is for a digital printer. A low-cost application program which runs under Windows™, includes the facility to create calibration curves. The reaction kinetics program, when used with the thermostatted cell holder accessory, provides an excellent low-cost enzyme analysis system.
See our Standards for UV-Vis spectrophotometers
Specifications of the Visible spectrophotometer Model M107
Display - 4 lines x 20-character LCD
Light source - Tungsten-Halogen
Monochromator - 1200 lines/mm grating
Detector - Silicon Photodiode
Wavelength Range - 325 - 1000nm
Wavelength Accuracy - ± 2 nm
Wavelength Repeatability - ± 1 nm
Noise - < 0.001A @ 500nm 0A
Zero Drift - < 0.003A per hour after warm-up
Bandpass - 5 nm
Stray Light - <0.1%T @ 340 nm
Photometric Accuracy - +/- 1% 0-2 A
Photometric Range - -1 to 2.5A, 0-125%T and
-9999C and +9999C
Printer Interface - RS 232 for printer
Computer Interface - USB for PC control
Power Requirements - 110/120V, 220/230V,
50/60 Hz, 60VA
Dimensions - 420 x 330 x 180mm packed 645 x
535 x 370mm
Weight - 7Kg packed 10Kg


https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077177/kgzmam2zphoi48exja0k.jpg

#M108 CAMSPEC M108 Visible spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077302/fhouokznlqrlqdlhxr5w.jpg
This Programmable Visible spectrophotometer is a full QC instrument. Using a reconfigured grating monochromator from the successful M105, M106 and M107, the M108 offers more performance and versatility with only a modest price difference. The large sample compartment allows the use of a wide range of accessories, including a 4-position cell changer with holder for cell pathlengths up to 50mm. A membrane keypad positioned next to the large, clear LCD display, allows the operator to rapidly switch between the %Transmission, Absorbance and Concentration modes and to set Zero.

Signal processing and results display are microprocessor controlled and the narrow 5nm bandpass gives improved analytical sensitivity. The outstanding optical performance is also indicated by the low zero drift (less than 0.001 Abs/Hour) and the low stray light (0.1%T @ 340nm).
The RS232 output provides a convenient link to a PC or serial printer for hardcopy. A low-cost application program which runs under WindowsTM includes the facility to create calibration curves. The reaction kinetics program, when used with the thermostatted cell holder accessory, provides an excellent low-cost enzyme analysis system.
This is the latest addition to our M100 Series of Visible Spectrophotometers. The replacement of the manual wavelength/filter control knob of the popular M107, by processor controlled stepper motors allows a step change in capabilities. The M108 has a 4 line x 20-character display and a 9-button keypad to allow easy use and full access to this intelligent spectrophotometer.
See our Standards for UV-Vis spectrophotometers
Features of the M108 visible spectrophotometer
• Stepper motors for wavelength and filters
• Stores up to 200 methods/results
• Concentration calibration: up to 8 standards up to 3 replicates linear or linear through zero
• USB for PC control and RS232 serial output for printer
• Data output includes method number and name, wavelength, date and time, %T, Abs concentration, unit
• Selectable wavelength calibration and dark current measurement
• 325 - 1000nm wavelength range
• 5nm bandwidth
• Low stray light (0.1%T at 340nm)
• Large sample compartment (up to 50mm pathlength cells)
• Large selection of accessories
• Manual 4-cell changer, with a pair of 10mm glass cells included
• PC Application Software option forwavelength scanning concentration curves ×can

The M107/M108 sample compartment (155 x 70 x 85mm) enables accessories to be exchanged in a few seconds.
10mm single cell or flowcell holder, P/N 107-102. Accepts standard rectangular and 4mm semi-micro 10mm pathlength cells, or a 10mm pathlengthflowcell with Z=8.5mm.
Test-tube holder, P/N 107-101. This V-type round test-tube holder holds tubes of diameters from 10 to 25mm. The access hole in the sample compartment lid means that any height test-tube can be used. The design of the holder ensures the tube is always central in the light beam. This means that the light beam is not bent and so remains aligned with the detector. This accessory is mounted on the same base-plate as the single cell holder.
Thermostatted cell holder and front panel, P/N 107-105. Accepts a standard rectangular 10mm pathlength macro or 4mm semi-micro cell. Requires connection to an external circulating water bath.
Standard Four-position manual cell changer, P/N 107-103. (Supplied with M108). Accepts four standard rectangular 10mm pathlength macro or 4mm semi-micro cells. The mechanical locating of the cell positions is very positive, giving excellent reproducibility.
Long pathlength Four-position manual cell changer, P/N 107-104. Accepts four standard rectangular 10-50mm pathlength macro cells.
M108 PC Application Software, P/N 108-110. For up to 3rd order concentration curves, timescans and wavelength scanning.
Printer, P/N 330-100. 40 character impact printer including battery charger, spare ribbon and spare paper roll.
Specifications of the M108 visible spectrophotometer
Display - 4 lines x 20 character LCD
Light source - Tungsten-Halogen
Monochromator - 1200 lines/mm grating
Detector - Silicon Photodiode
Wavelength Range - 325 - 1000nm
Wavelength Accuracy - ± 2 nm
Wavelength Repeatability - ± 1 nm
Noise - < 0.001A @ 500nm 0A
Zero Drift - < 0.003A per hour after warm-up
Bandpass - 5 nm
Stray Light - <0.1%T @ 340 nm
Photometric Accuracy - +/- 1% 0-2 A
Photometric Range - -1 to 2.5A, 0-125%T and -9999C and +9999C
Printer Interface - RS 232 for printer
Computer Interface - USB for PC control
Power Requirements - 110/120V, 220/230V, 50/60 Hz, 60VA
Dimensions - 420 x 330 x 180mm packed 645 x 535 x 370mm
Weight - 7Kg packed 10Kg

https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077302/fhouokznlqrlqdlhxr5w.jpg

#M508 CAMSPEC M508 single beam UV-Vis spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077416/tmmefajediewhmfw7zci.jpg
The M508 QC programmable single beam UV-Vis Spectrophotometer includes a 4 line x 20 character LCD display with a 9 button keypad and stepper motors for wavelength and filters. It can store up to 200 methods and results for big analytical projects.Data output includes method number and name, wavelength, date and time, %T, Abs, concentration, unit selectable wavelength calibration and dark current measurement.
This manual spectrophotometer incorporates a 200 - 1000nm wavelength range and 5nm bandwidth with low stray light (0.1%T at 220nm and 340nm).
It also comes complete with a manual 4-cell changer with 2 x 10mm UV cells and 4 x 10mm glass cells. Also PC Application Software is an option for concentration curves, timescan and wavelength scanning.
View the PDF below to see a selection of the many accessories that may be used with the M508. Please enquire if your requirements are not listed.
Main Features
• Stepper motors for wavelength and filters
• Stores up to 200 methods/results
• Concentration calibration: up to 8 standards and up to 3 replicates, linear or linear through zero
• Selectable wavelength calibration and dark current measurement
• 200 - 1000nm wavelength range
• 5nm bandwidth
• Low stray light (0.1%T at 220nm and 340nm)
• Large sample compartment (up to 100mm pathlength cells)
• 2 x 10mm UV cells and 4 x 10mm glass cells included
• Large selection of accessories • Manual 4-cell changer
• PC Application Software option for wavelength scanning,concentration curves and timescan.
See our Standards for UV-Vis spectrophotometers
Specification of the M508 UV-Vis spectrophotometer
Display 4 lines x 20 character LCD LCD
Light sources Tungsten-Halogen and Deuterium
Monochromator 1200 lines/mm grating
Detectors Silicon Photodiode
Wavelength Range 200 - 1000nm
Wavelength Accuracy ± 2 nm
Wavelength Repeatability ± 1 nm
Noise < 0.001A @ 500nm 0A
Zero Drift < 0.003A per hour after warm-up
Bandpass 5 nm
Stray Light <0.1%T @ 220nm and 340 nm
Photometric Accuracy +/- 1% 0-2 A
Photometric Range -1 to 2.5A, 0-125%T and -9999C and +9999C
Printer Interface RS 232 for printer
Computer Interface USB for PC control
Power Requirements 110/120V, 220/230V, 50/60 Hz, 135VA
Dimensions 510 x 420 x 210 packed 645 x 535 x 370
Weight 14Kg packed 17Kg

https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077416/tmmefajediewhmfw7zci.jpg

#M501 CAMSPEC M501 Scanning Single Beam Spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077623/fbvmjjflviw8fk1clusr.jpg
This is the Single beam scanning UV-Vis spectrophotometer M501 with an on-board LED display and keypad offering local control. The instrument can be linked and controlled by a PC via UV Analyst software.
See our NEWS for more info on the M501
The sealed and solvent-resistant tactile keypad has an alpha-numeric entry for user file names and user entry of units making it a practical and methodical instrument. The M501 also has a real-time clock for date and time stamping of results to help with organisation and clarity of analysis. There is also the option of monitoring the useage status of the lamps for maximum longevity and optimum performance.

The M501 now has a USB data port to enable file transfers
See our Standards for UV-Vis spectrophotometers
Operating features:
• Local Control Software - All methods are included
• Basic Mode - Measures Absorbance, %T and Concentration.
• Quantitative – Up to 10 standard solutions maybe used for a calibration
• Wavelength Scanning
• Kinetics - For time course scanning or reaction rates
• DNA/Protein – Concentration & DNA Purity are calculated
• Multi-wavelength - up to 10 wavelengths
• Performance Validation - for the GLP compliant laboratory
User Interface
The user interface of the M501 Single Beam Spectrophotometer includes Basic Mode (Abs, %T, Conc), Quantitative (concentration calibration curves), Wavelength Scanning, Kinetics (including timedrive), DNA/Protein, Multi-wavelength and Performance Validation. In Basic Mode, the result is continuously displayed (no need to “press to read”)
PC Control
TheM501 has a 2 x USB2 outputs. One for the download of data to a USB Memory stick to be analysed offline and one for the control of the spectrophotometer when the UV/VIS Analyst software is purchased. Comprehensive Camspec Application Software is available, together with small PC programs, dedicated to specialist tasks.
Specifications
Baseline Flatness ± 0.005 (After 1 Hr warm up 1100 – 200nm)
Zero Drift < 0.003A per hour after warm-up
Baseline Stability ± 0.001A
Bandpass 4nm (2nm option)
Stray Light (A.S.T.M.) <0.05%T @ 220nm and 340nm
Photometric Repeatability ± 0.002 Abs
Photometric Accuracy Better than 1% @ 0.5A, 1A, 2A
Photometric Range -0.7 to 3A, 0 to 200%T, 0 to 9999 Conc
Printer Interface Centronic parallel for A4 inkjet printers
Computer Interface USB Port
Power Requirements 110/120V, 220/230V, 50/60 Hz, 110VA
Dimensions 550 x 420 x 270 packed size 645 x 535 x 370
Weight 18kg Nett 24Kg Packed weight

https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077623/fbvmjjflviw8fk1clusr.jpg

#M550 CAMSPEC M550 True double beam UV Vis scanning spectrophotometer

https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077760/sopi0ecrreeysb4eatkf.jpg
CAMSPEC M550 True double beam UV Vis scanning spectrophotometer
This instrument is a True double beam UV Vis scanning spectrophotometer M550 with parallel sample and reference beams. The specification is as expected from a top-of-the-range instrument designed for research as well as routine use.
The M550 may be controlled by either UV Analyst or CamSpec Panorama software which is 21 CFR Part II compliant. This means that it can be used for pharmaceutical analysis requiring FDA (US Food and Drug Administration) approval.
See our Standards for UV-Vis spectrophotometers
We are an ISO 9001:2015 company, so all instruments are individually checked using wavelength and absorbance standards calibrated to international standards. All Standards are calibrated to UKAS, NIST or NPL.
The M550 fully complies with CE requirements for safety and ESD / EMC emission and susceptibility.
The M550 now has a USB data port to enable file transfers
The M550 has a USB interface for transfer of results to a PC and for PC control of the M550. The comprehensive Camspec UV-Analyst application software is available, together with a number of small PC programs dedicated to specialist tasks.
Technical Specifications for the M550 UV/VIS Spectrophotometer

Display 1/4 VGA 320x240pixels backlit LCD
Light sources Tungsten-Halogen and Deuterium
Monochromator Littrow type with 1200 lines/mm grating
Scan Speed Up to 2500 nm/min (return 3000nm/min)
Detectors Silicon Photodiodes
Wavelength Range 190 - 1100nm
Wavelength Accuracy ± 0.3nm
Wavelength Resolution 0.1nm
Wavelength Repeatability ± 0.05nm
Baseline Flatness ± 0.002 (After 1 Hr warm up 1100 – 200nm)
Zero Drift < 0.001A per hour after warm-up
Noise ± 0.0001A @ 500nm 0A
Bandpass 1.5nm
Stray Light (A.S.T.M.) KCl>2A at 198nm <0.05%T @ 220nm & 340nm
Photometric Accuracy ± 0.5% at 0.5A, 1.0A and 2.0A
Photometric Range -0.3 to 3A, 0 to 200%T, 0 to 9999 Conc
Printer Interface Parallel for A4 HP and Epson printers
Computer Interface USB Port
Power Requirements 110/120V, 220/230V, 50/60 Hz, 110VA
Dimensions 630 x 410 x 280mm packed 770 x 560 x 410
Weight 24kg packed 28Kg


https://camspec.eu/
Spectrophotometers - Single and Double Beam UV & Visible UV/Vis
Supplied Serviced & Calibrated in Cork, Ireland.
We Service and Calibrate in our workshop with two day turnaround.
INFO@QLIMITED.COM
https://res.cloudinary.com/hzd4uftbg/image/upload/v1508077760/sopi0ecrreeysb4eatkf.jpg